Clearone Interact Serial Command Guide Bedienungsanleitung Seite 49

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 61
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 48
Page 44 of 56
RESETUSB Reset USB
This command resets the USB interface on the COM module and causes the USB to re-enumerate.
ARGUMENT DETAILS
Name Type Size Values
Rsvd Unsigned Short 4 -
TEXT FORM DETAILS
COMMAND FORM:DEVICE RESETUSB [Value]
RFVER RF Version
This command reports the version of the microcontroller code for the RF in the USB/Headset Break Out Box.
This command is read only.
ARGUMENT DETAILS
Name Type Size Values
Value String 12 (Sent with a Null in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE RFVER [Value]
RING Ring Indication
This command indicates a ringing line. This command is reportable only. It cannot be queried or set.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 17 (R)
Value Unsigned Integer 2
0 = Ring cycle has stopped
1 = Ring cycle has begun
TEXT FORM DETAILS
COMMAND FORM:DEVICE RING <Channel><Value>
RINGEREN Ringer Enable
This command selects/reports the status of the audible ring indication.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 17 (R)
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICERINGEREN <Channel>
Seitenansicht 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 60 61

Kommentare zu diesen Handbüchern

Keine Kommentare