
Page 26 of 56
FILTER – Filter Parameters
This command selects/reports the parameters for a filter on a microphone.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 3, 5 (M, P)
Node Unsigned Integer 1
1 – 3 for Group 3 (M)
1 – 4 for Group 5 (P)
Type Unsigned Integer 1
Group 3 (M) Group 5 (P)
0 = None X X
1 = All Pass X X
2 = Low Pass X X
3 = High Pass X
4 = Low Shelf X
5 = High Shelf X
6 = PEQ X X
7 = CD Horn X
11 = Notch X X
Frequency Unsigned Float 4
Type Values
0 0 (NULL in text)
2 – 11 20.00 to 20000.00 Hz
Gain Signed Float 2
Type Values
0 – 3, 11 0 (NULL in text)
6 -15.00 15.00 dB
Bandwidth Unsigned Float 2
Type Values
0 – 3 0 (NULL in text)
6, 11 0.05 – 5.00 Octaves
TEXT FORM DETAILS
COMMAND FORM:DEVICE FILTER <Channel> <Node> [Type Frequency Gain Bandwidth]
FLOW – Flow Control
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is
implemented using DTR and DSR.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Integer 4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE FLOW [Value]
Kommentare zu diesen Handbüchern