5 - 3
Codabar
<Default All Codabar Settings>
Codabar On/Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the sled to read only Codabar bar codes with Modulo 16 check
characters. Default = No Check Character.
No Check Character indicates that the sled reads and transmits bar code
data with or without a check character.
When Check Character is set to Validate and Transmit, the sled will only
read Codabar bar codes printed with a check character, and will transmit
this character at the end of the scanned data.